Automation

A flow does not start a second time: check re-entry and cooldown

A flow test succeeds, but repeating the same keyword minutes later does not start it again.

2 min readLast updated November 4, 2026
An operations specialist arranging a customer conversation workflow

A flow test succeeds, but repeating the same keyword minutes later does not start it again. The team may suspect a missing message or broken trigger. When the incoming record exists, inspect settings governing another entry rather than keyword matching alone.

Review the return policy

Taloo checks re-entry policy among new-run conditions. Selecting once blocks another entry when a previous run exists for that flow and contact. Cooldown blocks entry within the configured interval after an earlier start. These checks do not themselves establish that the earlier run completed successfully.

An attempt ending unexpectedly can therefore affect a second test depending on settings and stored history. Inspect the run, starting time and intended contact instead of repeating messages indefinitely. Use an appropriate test contact when a genuinely independent initial entry is needed.

Distinguish cooldown, delay and sending window

Cooldown governs permission to start again; it does not promise a message when the interval ends. A delay inside an existing journey follows another path. The WhatsApp window governs sending eligibility and does not reopen simply because cooldown elapsed.

A journey already waiting for an answer is another consideration. An incoming message may continue it rather than start another run, while human control may prevent automation replies. Investigate these separately rather than changing entry policy when the real cause is ongoing execution or employee ownership.

Choose policy for the journey's purpose

Initial orientation may need less repetition than a route receiving recurring requests. Record the business reason and who needs to return and when. Do not make once the default for every flow merely to reduce replies in one test.

The current history check concerns the flow and contact. Do not assume an independent counter for every attempt on every number within the same flow. Test number context when relevant to the organisation and review automation execution scope.

Acceptance should include initial entry, return during cooldown, return afterwards and a contact with previous execution. Record the expected outcome for each setting. The team can then distinguish intentional repetition control from a case requiring correction.